Editing ATM Signaling and ILMI Parameters
9-29
Parameter: ILMI Get Next Timer
Default: 3
Range: 1 to 120
Function: Defines the ILMI Get Next Request timer value (in seconds). The Get
Next Request timer sets the amount of time allowed to receive a
GET_NEXT_RESPONSE message after sending a
GET_NEXT_REQUEST message.
Instructions: Accept the default, 3, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.9.1.15
Parameter: ILMI Get Next Retry Count
Default: 3
Range: 1 to 100
Function: Specifies the number of retransmissions of the ILMI
GET_NEXT_REQUEST message before the link is considered down.
Instructions: Accept the default, 3, or enter a value from 1 to 100.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.9.1.16
Parameter: ILMI Set Timer
Default: 3
Range: 1 to 120
Function: Defines the ILMI Set Request timer value (in seconds). The Set Request
timer sets the amount of time allowed to receive a SET_RESPONSE
message after sending a SET_REQUEST message.
Instructions: Accept the default, 3, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.9.1.17