About changing components
Except for memory cards, cards and external expansions modules must only be removed and
added to an B5800 Branch Gateway system when the system is turned off. See
Memory card
removal on page 261 and System shutdown on page 208 for more information.
Note that for extension ports, by default both an extension entry and a user entry are configured
in the system. Extension entries can be deleted without deleting the corresponding user entry.
This allows retention of the user settings and association of the user with a different extension
by changing that extension's Base Extension number to match the user's Extension ID.
In the following procedures, the term component refers to a card fitted into the control unit or
an external expansion module.
Replacing a component with one of the same type
About this task
If you are replacing a component with one of the same type and capacity, no configuration
changes are required.
Procedure
1. Turn the B5800 Branch Gateway system off. See System shutdown on page 208.
2. Remove the card or external expansion module.
Note:
The card slot or expansion port used as the replacement must be installed in the
same position.
3. Install the replacement using the appropriate procedure for the type of component.
See
Base and trunk card installation on page 61 or Connecting external expansion
modules on page 72 for more information.
4. Restart the B5800 Branch Gateway system.
About changing components
Implementing B5800 Branch Gateway for a CS 1000 Configuration October 2012 211
Vista de página 210