The control unit will shutdown with the restart timer set to 10 minutes.
Rebooting the system
About this task
You can use Manager to reboot an B5800 Branch Gateway system.
Procedure
1. Start Manager.
2. Select File > Advanced > Reboot.
3. In the Select B5800 window, select the B5800 Branch Gateway system.
4. Enter your user name and password.
5. In the Reboot window, do one of the following:
• Select Immediate to reboot the system immediately.
• Select When Free to reboot the system when there are no calls in progress.
This selection can be combined with the Call Barring options.
• Select Timed and then specify a time in hours and minutes.
This reboots the system the same as When Free but first waits for a specific
time. After the specified time, the system waits for there to be no calls in
progress and then reboots. This selection can be combined with the Call
Barring options.
Note:
If the time is after midnight, the system's normal daily backup is canceled.
6. In the Call Barring section, select Incoming Calls and/or Outgoing Calls. These
settings are used when the reboot mode is When Free. They bar the sending or
receiving of any new calls.
7. Click OK.
Additional system procedures
210 Implementing B5800 Branch Gateway for a CS 1000 Configuration October 2012