Chapter 1 Installing the Companion system 21
Business Communications Manager Companion Configuration Guide
RPI output connections
Feed the output pairs in through the bottom of the RPI and route the pairs to the output connectors.
The following figure shows how to route the output pairs. If you use one pair to power a base
station, connect the power pair to -PWR(1) and +PWR(1). If you use two pairs to power a base
station, connect one pair to -PWR(1) and +PWR(1), and the second pair to -PWR(2) and
+PWR(2).
Figure 7 Output connector pinout
RPI input connections
Feed the TCM input pairs from the Business Communications Manager distribution frame through
the top of the RPI and route them to the input connectors (IBIX1 to IBIX4).
The following figure shows how to route the input pairs. The maximum number of input pairs in
an RPI installation is 16.
Figure 8 Input connector pinout
Caution: Ensure both pairs have the same polarity.
If you connect two power pairs with opposite polarities, you can damage the base station
and RPI.
OBIXn
-PWR(1)
TCM
TCM
+PWR(1)
-PWR(2)
+PWR(2)
OBIXn
-PWR(1)
-PWR(2)
TCM
TCM
+PWR(1)
+PWR(2)
IBIXn
Pin 3 Pin 1
Pin 2Pin 4Pin 6Pin 8
Pin 5Pin 7
Pin 7
IBIXn
Pin 5 Pin 3 Pin 1
Pin 8Pin 6Pin 4Pin 2