Customizing Signaling
117374-C Rev 00
5-9
Setting Connection Thresholds
Connection thresholds allow you to control the number of point-to-point
connections, point-to-multipoint connections, and parties in a multipoint
connection allowed on the circuit at any given time.
Setting the Maximum Number of Point-to-Point Connections
By default, you can have up to 1000 simultaneous point-to-point connections on a
circuit at any given time. However, you can specify a value from 0 to 32767
connections.
Using the BCC
To change the maximum number of point-to-point connections, navigate to the
signaling prompt (for example,
box; atm/11/1; signaling/11/1
) and enter:
point-to-point-maximum
<integer>
integer
is a value from 0 to 32767.
For example, the following command sets the maximum number of point-to-point
connections on the ATM circuit to 2000:
signaling/11/1# point-to-point-maximum 2000
signaling/11/1#