Customizing an ATM Interface
117374-C Rev 00
4-15
Using Site Manager
To enable or disable per-VC clipping, complete the following tasks:
Disabling and Reenabling an ATM Interface
By default, the ATM interface is enabled when you create the circuit. However,
you can disable or reenable the interface at any time.
When the interface is enabled, traffic can flow over the interface. When the
interface is disabled, traffic cannot flow over the interface.
Using the BCC
To disable the ATM logical interface, navigate to the ATM interface prompt (for
example,
box; atm/11/1; atm-interface/11/1
) and enter:
state disabled
For example, the following command disables the ATM interface:
atm-interface/11/1#
state disabled
atm-interface/11/1#
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM link module interface
(
ATM1
) that you want to modify.
The Select Connection Type window
opens.
2. Click on
Line Attributes
. The ATM/ARE Line Driver Attributes
window opens.
3. Set the
Per-VC Clipping
parameter. Click
on
Help
or see the parameter description
on page A-11.
4. Click on
OK
. You return to the Select Connection Type
window.
5. Click on
Done
. You return to the Configuration Manager
window.
Comentários a estes Manuais