Editing APPN Parameters
114049 Rev. A 3-41
Parameter: Link Address (hex)
Default: None
Options: None
Function: Specifies the MAC/SAP, DLCI/SAP (for Frame Relay), or SDLC address
that this adjacent link station will use. This field displays the address you
specified when you added the adjacent link station. The MAC address
starts with the 0x prefix and ends with the SAP value.
Instructions: If you choose to specify a new link data address, specify the MAC address
in MSB noncanonical format with the 0x prefix, and end the address with
the SAP value. For Frame Relay, specify a valid DLCI and SAP value.
For SDLC, specify a valid SDLC address.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.4.1.27
Parameter: Max Send BTU Size
Default: 2057
Range: 256 to 4105
Function: Specifies the maximum Basic Transmission Unit (BTU) size that can be
sent over this TG to an adjacent link station. Each link station determines
its own maximum send BTU size based on local node definitions and
exchange identification (XID) information received from the interface and
the adjacent link station.
Instructions: Enter a number in the range 256 to 4105.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.4.1.14