42 Interworking requirements with CS 1000
You can use one of the two following methods to calculate the PSTN
trunks and SIP Access Ports:
"Trunk calculation: Method 1" (page 42)
"Trunk calculation: Method 2" (page 43)
To calculate the number of UEXTs required, see "UEXT calculations"
(page 46).
For more information about CS 1000 capacity, see Communication Server
1000E Planning and Engineering (NN43041-220).
Trunk calculation: Method 1
Follow these steps:
1. Add the number of client users.
2. Locate the resulting number in the Number of Users column in Table 5
"Poisson trunk table" (page 42).
3. Select the appropriate PSTN and SIP Access Port parameters based
on the required CCS per Users.
Table 5 "Poisson trunk table" (page 42) uses a Poisson value of P.01,
which represents 1 percent blocking.
Table 5
Poisson trunk table
Number of
users Parameter
Up to 6
CCS per
User
Up to 12
CCS per
User
Up to 18
CCS per
User
Up to 24
CCS per
User
PSTN 5 6 6 6
6 SIP Access Port 10 12 12 12
PSTN 7 10 12 12
12 SIP Access Port 14 20 24 24
PSTN 9 13 18 18
18 SIP Access Port 18 26 36 36
PSTN 10 16 22 24
24 SIP Access Port 20 32 44 48
PSTN 17 28 38 48
50 SIP Access Port 34 56 76 96
PSTN 22 38 53 68
75 SIP Access Port 44 76 106 136
PSTN 28 48 68 87
100 SIP Access Port 56 96 136 174
Nortel Mobile Communication 3100
Nortel Mobile Communication 3100 Planning and Engineering
NN42030-200 03.04 17 July 2009
Copyright © 2007-2009 Nortel Networks. All Rights Reserved.
.
Vista de página 41