38 Interworking requirements with CS 1000
correct Calling Line ID (CLID) and have the same Network Class of
Service (NCOS) as a call from the associated communication server
telephone.
The output for the WNK/WNK Virtual Trunk, from Element Manager or a
terminal window, looks like this:
DES IPTIE
TN 081 0 00 02 VIRTUAL
TYPE IPTI
CDEN 8D
CUST 0
XTRK VTRK
ZONE 000
TRK ANLG
NCOS 0
RTMB 10 3
CHID 3
TGAR 0
STRI/STRO WNK WNK
SUPN YES
AST NO
IAPG 0 *
CLS UNR DIP WTA LPR APN THFD XREP
P10 NTC MID
TKID *
AACR NO
Attention: All of the SIP Virtual Trunks must be configured to WNK
WNK.
The output for the ESN5 Route Data Block, from Element Manager or a
terminal window, looks like this:
TYPE RDB
CUST 00
DMOD
ROUT 10
DES IPROUTE
TKTP TIE
...
VTRK YES
ZONE 100