Configuring ATM Services
A-4
117374-B Rev. 00
ATM Line Parameters
The type of ATM link module you use determines the line details you can edit.
This section describes how to edit the line details for ATM ARE link modules and
the Model 5782 ATM routers.
Parameter: Enable
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables the line driver.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.2
Parameter: Interface MTU
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: 4608
Options: 1 to 9188
Function: Specifies the largest packet size (in octets) that the router can transmit on this
interface.
Instructions: Enter a value that is appropriate for the network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.9