Configuring ATM Services
4-48
117374-B Rev. 00
Using Site Manager
To change the signaling control VC MBS value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling Attributes
. The ATM Signaling Parameters window
opens.
3. Click on
Sig VC
. The ATM Control VC for Signaling
window opens.
4. Set the
Xmit Burst Size (cells)
parameter. Click on
Help
or see the
parameter description on page A-51.
5. Click on
Done
. You return to the ATM Signaling
Parameters window.
6. Click on
Done
. You return to the Edit ATM Connector
window.
7. Click on
Done
. You return to the Configuration Manager
window.