Configuring ATM Services
4-20
117374-B Rev. 00
drop-party-tx-
timer
T398 4 1 to 24 Specifies the Drop Party Sent timer value (in
seconds). This timer applies to multipoint
connections only and begins when the circuit sends
a DROP PARTY message to a party (the receiver of
the message) on the network.
The Drop Party Sent timer stops when the circuit
receives a DROP PARTY ACKNOWLEDGE
message (indicating that the end point used for the
party has been released) or a RELEASE message
(indicating that the end point used for the party has
been released and there are no remaining parties).
add-party-tx-
timer
T399 14 1 to 84 Specifies the Add Party Sent timer value (in
seconds). This timer applies to multipoint
connections only and begins when the circuit sends
an ADD PARTY message to a party (the receiver of
the message) on the network.
The Add Party Sent timer stops when the circuit
receives an ADD PARTY ACKNOWLEDGE
message (indicating the connection to the party), an
ADD PARTY REJECT message (indicating the
inability to add the party), or a RELEASE message
(indicating the inability to add the party and the
absence of any remaining parties).
If the timer expires before the circuit receives an
ADD PARTY ACKNOWLEDGE, ADD PARTY
REJECT, or RELEASE message, the circuit clears
the party.
Table 4-1. Signaling Timer Descriptions
(continued)
BCC
Name
Site
Manager
Name
Default
Value Range Description