Installing Synchronous Net Modules in an ASN Platform
Cabling Requirements for the Net Modules24 BNX Software Version <x.x> Test Part Number
Net Module to an RS-422 Dial-on-Demand and Dial Backup Device
The cabling requirement for a Dual Sync net module to an RS-422 WAN
dial-on-demand and dial backup device is a 44-pin D-Sub to RS-422: Raise DTR
cable, Order No. 7139 (Table A-15 and Figure A-13).
Table A-15. Pin-to-Pin Connections for the 44-Pin D-Sub to RS-422:
Raise DTR Cable (Order No. 7139)
Bay Networks Termination Remote Termination
Signal Pin to Pin Signal
Send Data+ 2 4 Send Data A
Send Data- 16 22 Send Data B
Receive Data+ 3 6 Receive Data A
Receive Data- 17 24 Receive Data B
Request to Send+ 4 7 Request to Send A
Request to Send- 18 25 Request to Send B
Clear to Send+ 5 9 Clear to Send A
Clear to Send- 19 27 Clear to Send B
Data Set Ready+ 6 11 Data Mode A
Data Set Ready- 20 29 Data Mode B
Terminal Ready+ 8 12 Data Terminal Ready A
Terminal Ready- 22 30 Data Terminal Ready B
Data Carrier Detect+ 9 15 Ring Indicator
Send Timing+ 10 5 Send Timing A
Send Timing- 24 23 Send Timing B
Receive Timing+ 11 8 Receive Timing A
Receive Timing- 25 26 Receive Timing B
Terminal Timing+ 12 17 Terminal Timing A
Terminal Timing- 26 35 Terminal Timing B