Avaya BayRS, BCC, and Site Manager Software Version 15.3.0.0 Fixed Anomalies Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Routers Avaya BayRS, BCC, and Site Manager Software Version 15.3.0.0 Fixed Anomalies. Avaya BayRS, BCC, and Site Manager Software Version 15.3.0.0 Fixed Anomalies User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 8
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
Router/BCC Fixed Anomalies for BayRS 15.3.0.0
Q00103090-02: Frame Relay
IP Circuit remains up after a sync interface configured with Frame Relay is disabled.
Q00153152-01: Web Server
Memory leak occurs when HTTP connections fail. This may result in an out of memory fault on the
router if this happens continuously.
Q00154341-02: ATM
Copying an ATM PVC using Site Manager gives an erroneous error message in the log message.
However, the ATM PVC is configured correctly and does come up.
Q00156640-01: ATM_PQ
Multiple attempts are required to delete ATM priority queuing.
Q00174118-01: NAT/ECMP
In a NAT with RIP2 ECMP configuration, changing between Multiple Next Hop Calculation
Methods may result in a fault on the router.
Q00135161-01: Scripts
Using install.bat to configure Frame Relay on an T1/FT1 interface will prevent Site Manager from
being able to open the configuration file. However, the router will still be able to boot using the
configuration file.
Q00152764-01: IP Traffic Filters
Enabling Extended Traffic Filter support with inbound traffic filters with user defined IP criteria
configured will cause the router to fault.
Q00173189: Radius
Memory corruption may occur when a remote Radius slot goes down.
Q00051621-03: Diffserv
Diffserv is not working for the filters that use a criteria of URL.
Q00059191-03: TI
Unable to save the configuration after many dynamic changes on very large configuration file.
Q00103537-02: Scripts
inst_pp5430.bat does not support the T3/E3 ATM PMC module.
Q00168709-01: Radius Accounting
Different session IDs are used for the Radius accounting stop and start messages for TI sessions
making it difficult to correlate the start/stop pairs for each session.
Q00174392-02: OSPF
Incorrect mask is being installed for the default router during network convergence. In redundant
topologies if there is more than one exit out of the autonomous system via a default route then
there could be a connectivity issue when the network converges due to the fact that one of the exit
points is now unavailable.
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1

1 Router/BCC Fixed Anomalies for BayRS 15.3.0.0 Q00103090-02: Frame Relay IP Circuit remains up after a sync interface configured with Frame Relay

Página 2

2 Q00175589-01: Radius The audit feature does not work for users authenticated via Radius. Q00175750-01: ATM A fault occurs when deleting an ATM s

Página 3

3 Q00209477-01: Dial Backup The ifEntry.ifOperStatus and ifSpeed attributes are incorrect if a backup circuit is configured for the interface. Q001

Página 4

4 Q00228099: PP5430 ATM T1 Bouncing an PP5430 ATM T1 interface under load may result in a fault on the router. Q00245641-01: TI The TI_INIT process

Página 5

5 Q00152897-02: ATMLANE In an ATMLANE bridging environment, after the ATM slot resets, the router does not respond to the LE_ARP from the switch cau

Página 6

6 Q00286620: Radius When the router receives incorrectly formatted Radius Authentication packets (i.e. the packet size is less than the minimum or

Página 7

7 Q00208761-01: Statistics Manager Creating a frame relay query in statistics manager using the wfCircuitShapeHiClippedPkts, wfCircuitShapeMediumCli

Página 8

8 Q00321950-01: Report Generator Report generator will not work on a 15.0.0.0 or greater configuration file that was saved on the router and copied

Comentários a estes Manuais

Sem comentários