Configuring Frame Relay Services
5-18
308624-14.10 Rev 01
Maximum SVCs
Maximum SVCs indicates the maximum number of simultaneous switched virtual
circuits allowed on the port. The more SVCs you allow, the larger the system
memory required to support them.
To set the maximum SVCs, navigate to the signalling prompt (for example,
box;
serial/1/2; frame-relay/1/2; signalling/3/2
) and enter:
maximum-svcs
<integer>
integer
is the number of SVCs allowed. The value can be from 1 to 2147483647.
The default is 100.
For example, the following command line sets a maximum of 200 SVCs:
signalling/3/2#
maximum-svcs 200
signalling/3/2#
Setup Timer
The setup timer indicates the number of seconds allowed from the time the router
sends a setup message to the called subscriber and receives a connect or call
proceeding message from that subscriber. If a timeout occurs, the router
retransmits the setup message and restarts the timer. If the timer expires a second
time, the router clears the call.
To set the setup timer, navigate to the signalling prompt (for example,
box;
serial/1/2; frame-relay/1/2; signalling/3/2
) and enter:
setup-timer
<integer>
integer
is the number of seconds allowed. The value can be from 2 to 90 seconds.
The default is 4.
For example, the following command line sets a timer of 10 seconds:
signalling/3/2#
setup-timer 10
signalling/3/2#