Configuring Data Compression Services
3-10
117352-C Rev. 00
Modifying the Buffer Size
To protect against data loss, modify the Buffer Size parameter. To modify this
parameter, access the WCP Line Interfaces List window.
For instructions on accessing configuration windows, see “Accessing
Configuration Windows” on page 3-2. For parameter descriptions, see
Appendix A, “Data Compression Parameters.”
Configuring Hardware Compression
There are issues specific to hardware compression:
• Selecting a hardware compression engine
• Selecting a fallback compression mode
These two issues are explained in the next sections.
Selecting Software or Hardware Compression Engines
When you configure a VC for compression, the default compression type varies
(Table 3-4
).
Table 3-4. Default Compression Type Dependencies
Module Type Default Compression Type
Link module that does not support
hardware compression
Software
Link module that supports hardware
compression
Hardware
Net module other than compression
module
Software
Net module (hardware compression net
module)
Hardware
Advanced compression coprocessor
daughterboard
Hardware
Comentários a estes Manuais