Installing the Backbone Link Node-2
109352-E Rev. A 2-7
Environmental Requirements
The installation site must meet the environmental requirements listed in Table 2-7.
Setting Up the Backbone Link Node-2
You must install your BLN-2 in an electronic enclosure rack.
Attaching Angle Brackets
We highly recommend that you place your hardware platform on angle brackets
for added support when installing your BLN-2 in a rack. You need the following
equipment to attach the angle brackets:
• The hardware package containing the angle brackets, panel-mount screws,
and cage nuts
• Tape measure
• Phillips screwdriver
• Pen or pencil
Attach the angle brackets to the rack as follows:
1. To ensure that the slots in the BLN-2 flanges align with the holes in the
rack:
a. Measure at least 15.75 in. (40 cm) of free vertical space inside the
rack and mark the spot.
Table 2-7. Environmental Requirements
Altitude Humidity Temperature
0 to 8000 ft
(0 to 2400 m)
10% to 90%
noncondensing
0°C to 40°C
(32
∞
F to 104
∞
F)
Caution: Before you set up your BLN-2, refer to “Space Requirements”
earlier in this chapter to verify that adequate space exists for heat exhaust.