Avaya DECT Messenger Fundamentals - Communication Server 1000 Manual do Utilizador Página 104

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 168
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 103
is an LRMS (E2) DECT handset, and the alarm was sent as a normal message, the
acknowledgement is automatically generated at the moment that the message arrives at
the device. If the alarm message was sent as an urgent message to an LRMS (E2) DECT
handset, the acknowledgement is received after the user presses the accept or del button
on the handset. See
Figure 33: Acknowledge sequences for Normal and Urgent
messages using DECT handsets on page 105.
• SET/RESET
An alarm can also be generated, based on a set command. This command must always
be followed by a reset from the same input module, after the alarm condition is no longer
active.
Figure 31: SET/RESET Alarm Structure on page 104 illustrates the SET/REST
alarm structure.
Figure 31: SET/RESET Alarm Structure
The input modules eCAP, eAPI, and eIO can generate a set/reset command. (eIO set/
reset is explained in more detail later on in this document.) An acknowledgment from a
device does not clear the alarm condition on that device in the database. Therefore, even
if the call on the device is answered, the alarm is not reset. As long as the eKERNEL does
not receive a reset from the Input Module, the alarm is repeated on the device with a time
interval that you must have specified in the eCONFIG.
Figure 32: Alarm processing
DECT Messenger Customer Engineer Manual
104 DECT Messenger Fundamentals March 2012
Vista de página 103