Applying Outbound Traffic Filters
117348-A Rev. A 7-5
5. Choose Criteria > Add > Datalink | IP >
criterion
.
To configure filters for IP-routed packets,
always choose IP instead of Datalink. See
Chapter
4 for information about the
outbound traffic filter criteria for IP and data
link headers.
The Add Range window opens.
6. Specify the range to apply to the
selected criterion.
To enter a hexadecimal number, use the
prefix 0x. Zero is not a valid entry. If the
range consists of just one value, specify
that value in both fields. See Chapter
5 for
information about common traffic filter
ranges.
7. Click on OK. The Create Priority/Outbound Template
window opens (Figure
7-4). The new
criterion and range appear in the Filter
Information field.
8. To add more ranges, choose Range >
Add.
You can add up to 100 ranges in each
template.
9. Choose Action > Add > Datalink
| IP >
action
.
For a Datalink criterion, choose a Datalink
action; for an IP criterion, choose an IP
action.
If you selected the Length action, the
Prioritization Length window opens
(Figure
7-5). See “Specifying Prioritization
Length” for instructions. Otherwise, the
Create Priority/Outbound Template window
opens, showing the criteria, range, and
action in the Filter Information field.
10.Click on OK. The Filter Template Management window
opens. The new template appears in the
templates list.
Site Manager Procedure
(continued)
You do this System responds