Configuring IP Utilities
A-16 117358-A Rev. A
Telnet Client Global Parameters
Use the following guidelines to configure the global parameters in the Edit Telnet
Client Global Parameters window..
Parameter: Enable/Disable
Path: Protocols > Global Protocols > Telnet Client > Global
Default: Enable
Range: None
Function: Specifies whether the Telnet client is enabled for the IP router, allowing you to
establish outbound Telnet sessions from the Technician Interface to another
router or to a UNIX station that supports Telnet.
Instructions: Select Enable to enable the Telnet client for the IP router or Disable to disable it.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.7.2.2
Parameter: Verbose Debug Logging
Path: Protocols > Global Protocols > Telnet Client > Global
Default: OFF
Options: ON
| OFF
Function: Specifies whether the Technician Interface displays the negotiation process
between the Telnet server and Telnet client. This parameter is for diagnostic use
only.
Instructions: Select ON to enable verbose debug logging or OFF to disable it.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.7.2.3