Vista de página 415
416 Module - eKERNEL
Figure 155
Watchdog enabled
Guarding
For every input program, the administrator can configure a guarding
facility, as shown in Figure 156 "Guarding information" (page 417).
If guarding is activated for a specific input program, an indication is given
in the Client information frame for every TCP/IP client.
The Guarding T/O field specifies the timeout that is defined in the
eKERNEL_guarding table, and the last event field text box shows the
number of seconds that have passed since the last request was received
from the TCP/IP client. Once the Last event value exceeds the guarding
timeout value, a guarding alarm is generated.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 1
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.