Functional description 319
For FIRE alarms, the group is FIRE and the alarm description is FIRE.
Messages are sent with the option: remove after *sent.
For MCP alarms, the group is MCP and the alarm description is MCP.
Messages are sent with the option: remove after *sent.
The message is retrieved from the remaining part of the line after FIRE or
MCP. For example, FIRE;FAP 1 BLOCK 2 LOWER GROUND FLOOR Z
returns the message FAP 1 BLOCK 2 LOWER GROUND FLOOR Z.
M-TECH
The valid manufacturer is M-TECH and the valid model is ESPRESSO.
Table 11
Sample M-TECH data
<00001/This is a sample message>
The first field starts between < and /, in the example 00001.
The second field starts between / and > in the sample M-TECH data
message.
The group is identified by the first fields, for example, 00001, and the
message is identified by the second field (This is a sample message).
Currently, alarms are sent with alarm description P0 and sent with option
Remove after *sent.
NIRA
The valid manufacturer is NIRA and the valid model is *BASE.
Nira is based upon installation Eeuwfeestkliniek Antwerpen.
Figure 72
Sample NIRA protocol data
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 1
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.