Avaya Configuring ATM Services Manual do Utilizador Página 376

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 426
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 375
Configuring ATM Services
A-78
308612-14.00 Rev 00
Parameter: OAM Threshold 1
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Service
Attributes > PVC
Default: 1
Options: 1 to 255
Function: Specifies the number of cells that the PVC can lose after not receiving an OAM
loopback response before declaring that the PVC service record is not
operational.
Instructions: Specify a threshold value from 1 to 255 cells.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.5.1.33
Parameter: OAM Threshold 2
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Service
Attributes > PVC
Default: 2
Options: 1 to 255
Function: Specifies the number of OAM loopback response cells that the PVC service
record must receive before declaring that the PVC is operational again.
Instructions: Specify a threshold value from 1 to 255 cells.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.5.1.34
Vista de página 375
1 2 ... 371 372 373 374 375 376 377 378 379 380 381 ... 425 426

Comentários a estes Manuais

Sem comentários