Avaya Configuring ATM Services Manual do Utilizador Página 137

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 426
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 136
Customizing Signaling
308612-14.00 Rev 00
4-21
disconnect-timer TDisc 4 1 to 180 Specifies the SAAL Data Link Disconnect timer
value (in seconds). This internal timer alerts upper
layers that the link is down. The timer begins if the
entire link goes down for any reason.
When the link goes down, the SAAL sends a
DISCONNECT REQUEST message to the
upper-layer application manager. The SAAL sends
a disconnect request every time the SAAL Data
Link Disconnect timer expires and continues to
send this message until the link becomes
operational.
alerting-rx-timer T397 180 180 to
1024
Specifies the Alerting Received timer value (in
seconds). This timer begins when the circuit
receives an ALERTING or ADD PARTY ALERTING
message over the signaling VC.
The Alerting Received timer stops when the circuit
receives an ADD PARTY ACKNOWLEDGE
message. The first time that the timer expires, the
circuit sends a DROP PART or RELEASE message.
When the timer expires a second time, the timer will
not restart.
This timer can be used with UNI Version 4.0 and
later.
(continued)
Table 4-1. Signaling Timer Descriptions
(continued)
BCC
Name
Site
Manager
Name
Default
Value Range Description
Vista de página 136