Configuring ATM Services
4-42
303514-A Rev. 00
Using Site Manager
To change the signaling PCR value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Confi
uration Mana
er window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling Attributes
.The ATM Si
nalin
Parameters window
opens.
3. Click on
Sig VC
. The ATM Control VC for Si
nalin
window opens.
4. Set the
Xmit Peak Cell Rate (cells/s)
parameter. Click on
Help
or see the
parameter description on pa
eA-49.
5. Click on
Done
. You return to the ATM Si
nalin
Parameters window.
6. Click on
Done
. You return to the Edit ATM Connector
window.
7. Click on
Done
. You return to the Confi
uration Mana
er
window.