114947-A Rev. A 3-1
Chapter 3
Checking Status Indicators
This chapter describes the status indicator lights (LEDs) on the Token Ring link
modules. Use the LEDs to verify that the link module is operating after
installation.
Figure
3-1 shows the LEDs on the Single, Dual, and Quad Token Ring link
modules. T
able 3-1 describes those LED functions.
Figure 3-1. Token Ring LEDs
Note: We recommend that you issue the diags command to the associated
slot, using the Bay Networks Technician Interface, immediately after you
insert a link module. (Refer to Using Technician Interface Software if you use
router software or Troubleshooting and Testing if you use BayStream
software.) Otherwise, the link module FAIL LED will remain lit, indicating
that diagnostics have not run on the Intelligent Link Interface (ILI). However,
even if you do not issue the
diags command, the link module initializes and
becomes operational as long as the board functions properly and contains the
correct interface configurations.
DTR
XCVR1
FAIL
NSRT
RCVR
WFAIL
XCVR2
NSRT
RCVR
WFAIL
FAIL
QTOK
WFAIL
NSRT
RCVR
WFAIL
NSRT
RCVR
WFAIL
NSRT
RCVR
WFAIL
NSRT
RCVR
MAU1
MAU2MAU3
MAU4
TOKEN
XCVR
FAIL
NSRT
RCVR
WFAIL
TKR0001A