Configuring Frame Relay Services
1-6
117376-C Rev. 00
Configuring PVCs and SVCs
You configure permanent virtual circuits (PVCs) and switched virtual circuits
(SVCs) after you enable frame relay.
Configuring a PVC
You can configure PVCs using either the default service record or by adding a
service record. Use these instuctions to configure PVCs on the default service
record. To configure PVCs on service records that you add, see "Adding PVCs to
Service Records" on page 3-14.
Using the BCC
To add a PVC to the default service record:
1.
Navigate to the frame-relay prompt.
For example:
box; frame-relay/1/2
2.
Navigate to the
default-service
prompt.
The BCC context changes to the default service record. For example:
frame-relay/1/2# default-service
default-service/1/2#
3.
Enter the
pvc dlci
<value>
command.
The service provider supplies the data link connection identifier (DLCI),
which uniquely identifies this PVC. See
Help
or the DLCI Number parameter
in Appendix A for more information.
For example:
default-service/1/2# pvc dlci 16
pvc/1/2/16#
You have added a PVC to the default service record. Repeat this procedure to add
more PVCs according to the requirements of your network.