BAYSTACK ADVANCED REMOTE NODE
SERIAL ADAPTER AND EXPANSION MODULES
READ ACROSS for minimum requirements
MINIMUM
Order#
Support
SOFTWARE
(Factory Install / Field Upgr.)
Description
CR
ID
Part #
Revision
(1)
REQUIRMENTS
(2)
CV0004001 / CV0011001
ARN SERIAL ADAPTOR MODULE *
8736 114013
2
V11.0/4N
CV0004002 / CV0011002
ARN ISDN BRI S/T (without NT1) ADAPTOR MODULE (6)
*
8784 114009
4
V11.0/4N
CV0004003 / CV0011003
ARN ISDN BRI U (with NT1) ADAPTOR MODULE *
8800 113448
1
V11.0/4N
CV0004004 / CV0011004
ARN 56/64K DSU/CSU ADAPTOR MODULE (6) *
8768 113437
B
V11.0/4N
CV0004005 / CV0011005
ARN V.34 MODEM ADAPTOR MODULE *
8752 113457
1
V11.0/4N
CV0004011 / CV0011011
ARN TRI-SERIAL PORT EXPANSION MODULE *
8848 113259
1
V11.0/4N
CV0004012 / CV0011012
ARN ETHERNET PORT EXPANSION MODULE *
8832 113242
1
V11.0/4N
ARN ETHERNET EXPANSION MODULE w/ DCM *
8928
1
V11.02 (3)
CV0004013 / CV0011013
ARN TOKEN RING PORT EXPANSION MODULE *
8816 113251
1
V11.0/4N
CV0004014 / CV0011014
ARN ETHERNET & TRI-SERIAL EXPANSION MODULE
*
8864 113034
1
V11.0/4N
ARN ENET & TRI-SERIAL EXPANSION MODULE w/ DCM *
8960
1
V11.02 (3)
CV0004015 / CV0011015
ARN TOKEN RING & TRI-SERIAL EXPANSION MODULE
*
8880 113121
1
V11.0/4N
CV0004020 / CV0011020
ARN V.34 MODEM CONSOLE MODULE *
8752 114017
1
V11.0/4N
CV0004021 / CV0011021
ARN ETHERNET DATA COLLECTION MODULE *
- 960-470-X
B
V11.02 (3)
CV0004022 / CV0011033
ARN X.25 PAD ADAPTOR & BREAKOUT BOX *
8808 115982-A
1
V12.10 (4)
CV0004023 / CV0011034
ARN T1/FT1 DSU/CSU ADAPTOR MODULE *
8776 114936-A
1
V12.10 (4)
CV0004024 / CV0011040
ARN E1/FE1 ADAPTOR MODULE (RJ) *
8780 118628-A
1
V12.20 (5)
CV0004025 / CV0011041
ARN E1/FE1 ADAPTOR MODULE (BNC) *
8780 118628-A
1
V12.20 (5)
CV0004026 / CV0011042
ARN ETHERNET & 7-SERIAL EXPANSION MODULE
*
8872 119413-A
1
V13.10
ARN ENET & 7-SERIAL EXPANSION MODULE w/ DCM *
8972
1
V13.10 (3)
CV0004027/CV0011043
ARN 7-SERIAL PORT EXPANSION MODULE *
8873 119414-A
1
V13.10
External Model number labeling refers to the base module’s LAN technology and DRAM size configuration only, and does not reflect
the presence of optional add-on Adapter or Expansion Modules
Notes:
(1) = All units at the Minimum Support Revision or higher are considered Year 2000 Compliant when operating with Router Software
V11.03 (Site Manager 5.03) or Router Software V12.0 Rev2 (Site Manager 6.0 Rev2) and higher.
(2) = Site Manager revision 5.00/4N or higher is required to manage the ARN platform correctly.
(3) = Diagnostic PROM code V1.30 or higher is required on the BayStack ARN Base Module to support the DCM Adapter.
(4) = Diagnostic PROM code V2.00 or higher is required on the BayStack ARN Base Module to support the X.25 PAD and T1/FT1 Adapter.
(5) = Diagnostic PROM code V2.06 or higher is required on the BayStack ARN Base Module to support the E1/FE1 Adapter.
(6) = The ISDN S/T Adapter Module (CV0004002 / CV0011002) must be at a minimum functional revision of 09 in order to insure
interoperability with a 56/64K CSU/DSU Adapter Module (CV0004004 / CV0011004) in the same Base unit.