16 Chapter 2 Configuring an analog device DN record
P1013653 02
Reviewing Set restrictions
1 Click on the key beside the Restrictions heading in the DN record.
2 Click on the Set restrictions heading.
Figure 9 Set restriction example
3 Ensure that the Allow Link set restriction is set to Y (Yes) for the analog device.
ATA use On site
Off site
Select the location of the analog device.
The Off site value is supported on analog devices connected to an ASM 8+
module.
Msg Indicate None
Tone
Lamp
Tone sends a Stutter Dial Tone through the telephone receiver when a message is
waiting.
Lamp turns on an indicator light on the telephone when a message is waiting.
The Lamp indication feature is only available for analog devices connected to an
ASM 8+ module.
ATA Dvc Modem
Telephon
Default: Modem
Analog devices can have connectivity issues over BRI/PRI lines. To alleviate this,
you can specify the type of device attached to the line.
Modem supports 3.1 Khz audio; which requires a higher quality of service on the
ISDN trunks. Modems and fax machines require this for reliable information
transfer. If the trunks cannot provide the higher level of service, the call will fail.
Telephon supports speech paths, which require less quality on the trunk; if used for
fax and/or modem, information transfer would be unreliable.
Disconnect
Supervision
Off
On
Default: Off
This setting is only available for analog devices connected to an ASM 8+ module
using the North American profile.
Set this value to On if you have an analog device that does not automatically
disconnect when the far end hangs up.
This enables the system to disconnect the line from the analog device once it
receives the disconnect signal from the far end.
Note: For a detailed explanation on all Set restriction settings, refer to the Business
Communications Manager Programming Operations Guide.
Table 10 ATA settings (Continued)
Attribute Values Description
Vista de página 15