Customizing Synchronous and Asynchronous Interfaces
115391-A Rev. A 5-23
KG84A Sync Loss Interval
By default, the BayStream software waits 50 cycles after detecting an FCS error
to receive a valid frame before declaring that a loss of synchronization has
occurred.
You can set the KG84A loss interval to 5, 10, 25, 50, 100, 200, or 500 cycles on
this interface.
KG84A Remote Resync Wait
By default, the BayStream software waits 200 cycles when synchronization is lost
and a remotely initiated resynchronization has been detected. You can set the
number of cycles that the BayStream software waits for the remote KG84A device
to complete a resynchronization operation to 2, 5, 10, 25, 50, 100, 200, or 500.
After this number of cycles, the BayStream software determines that the
resynchronization failed and initiates another resynchronization.
Note that if you press the RESYNC button on the local KG84A device, the
BayStream software responds as if it detected a remotely initiated
resynchronization.
Use different settings at each end of the point-to-point link to avoid a possible race
condition.
You can configure the KG84A resynchronization wait on this interface.
Site Manager: KG84A Sync Loss Interval parameter: page A-66