Installing SRM Link Modules in BN Platforms
3-2 115622-A Rev. A
The LEDs on the SRM-L indicate the following:
When the 12V 1 LED is not on:
The F7 fuse is blown in the BLN/BLN-2.
The F9 fuse is blown in the BCN.
When the 12V 2 LED is not on:
The F6 fuse is blown in the BLN/BLN-2.
The F12 fuse is blown in the BCN.
When lit, the VCC LED indicates that the power supply voltages are within
normal limits.