Configuring Frame Relay Services
A-34 117376-B Rev. 00
SVC Service Record Parameters
The following sections describe SVC service record parameters.
• SVC Service List Parameters
• SVC Options Parameters
• SVC Options List for Service Parameters
SVC Service List Parameters
You can edit SVC Service List parameters in the Frame Relay Service List
window (F
igure A-10). These parameters apply to all of the SVCs on the service
record, unless you configure SVCs individually with SVC Options parameters.
Parameter: Multiline Algorithm to Choose Line
Path: Configuration Manager > Protocols > Frame Relay > Services > Multiline
Default: None
Options: Random | Address Based
Function: Specifies how the multiline circuit distributes traffic over its data paths.
Instructions: To send data alternately over the two paths, select Random. This method
ensures even distribution among the lines, but the packets arrive out of
sequence. If the traffic between the same source and destination address pair is
always going over the same data path, select Address Based. This method
ensures the data arrives in sequence.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.1.1.23