Data Compression Overview
117352-E Rev 00
2-15
For more information about Bay Networks dial services, see Configuring Dial
Services.
X.25 Services
An X.25 network permits as many as 128 VCs to exist on the same physical link at
the same time. You can configure each of these interfaces individually to use data
compression or not.
X.25 PDN and DDN Services
When you use data compression on circuits that you configure for X.25 Public
Data Network (PDN) or Defense Department Network (DDN) services, you must
enable compression on both sides of the link. If you configure compression on
only one side of a PDN or DDN link, the data that travels over that link will be
corrupted.
You must also remember to enable the X.25 service record compression parameter
for each X.25 interface that you configure. For more information about this
parameter, see Configuring X.25 Services.
Adjusting X.25 Max Window Size
Window size can affect packet throughput across the X.25 network. Setting the
X.25 Max Window Size parameter too low can cause the router to drop packets
and render data compression ineffective. You should configure this parameter at a
higher value than the default setting, see Configuring X.25 Services.